Martin Audio ENGINEER Guia do Utilizador Página 76

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 75
Engineer 418 & 818 User Manual Page 76
To recall this preset we would now do the following:
Open a connection to the device
Set the RTS pen
Wait for 10 ms
Send package 254 14 0 0 255 12
Reset the RTS pin
Setting master- and zone volumes
Zone volumes can also be set using their respective index. As with the preset recalls, you can determine which
zone corresponds to a certain index from the Engineer control software:
In this example zone 1 is named “Dance Floor” and has outputs 1, 2 and 3 assigned to it which are labelled
“Sub”, “WT3 L” and “WT3 R”. Zones are indexed from 136: Zone 1 corresponds to index 136, zone 8
corresponds to index 144. The master volume's index is 84. These indices are referred to as “node-index”.
Gain values in the Engineer are indexed from -45 dB to +15 dB in steps of a quarter of a dB:
Index 0 1 2 .... 180 ... 239 240
Gain [dB] -45.00 -44.75 -44.50 0 dB +14.75 +15.00